- 800-399-6891
SMA couplers sample a portion of a signal, allowing for monitoring of a signal. We offer SMA couplers in various bandwidths, the wider the bandwidth the less the directivity. SMA Directional Couplers are commonly used in Cellular, DAS, and Military systems.
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
06 | 20 dB Min | 0.5 dB Max | |||
10 | 20 dB Min | 0.5 dB Max | |||
20 | 20 dB Min | 0.5 dB Max | |||
30 | 20 dB Min | 0.5 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
06 | 20 dB Min | 0.5 dB Max | |||
10 | 20 dB Min | 0.5 dB Max | |||
20 | 20 dB Min | 0.5 dB Max | |||
30 | 18 dB Min | 0.5 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
06 | 20 dB Min | 0.5 dB Max | |||
10 | 20 dB Min | 0.5 dB Max | |||
20 | 20 dB Min | 0.5 dB Max | |||
30 | 18 dB Min | 0.5 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
06 | 20 dB Min | 0.5 dB Max | |||
10 | 20 dB Min | 0.5 dB Max | |||
20 | 20 dB Min | 0.4 dB Max | |||
30 | 20 dB Min | 0.4 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
06 | 20 dB Min | 0.5 dB Max | |||
10 | 20 dB Min | 0.5 dB Max | |||
20 | 20 dB Min | 0.4 dB Max | |||
30 | 18 dB Min | 0.5 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
06 | 17 dB Min | 2.0 dB Max | |||
10 | 17 dB Min | 0.95 dB Max | |||
20 | 17 dB Min | 0.4 dB Max | |||
30 | 17 dB Min | 0.4 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
06 | 15 dB Min | 2.3 dB Max | |||
10 | 15 dB Min | 1.15 dB Max | |||
20 | 15 dB Min | 0.6 dB Max | |||
30 | 15 dB Min | 0.6 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
10 | 12 dB Min | 0.6 dB Max | |||
20 | 12 dB Min | 0.5 dB Max | |||
30 | 12 dB Min | 0.5 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
06C | 15 dB Min | 0.75 dB | |||
10C | 15 dB Min | 0.80 dB | |||
20C | 12 dB Min | 0.70 dB | |||
30C | 12 dB Min | 0.70 dB |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
10 | 10 dB Min | 2.6 dB Max | |||
20 | 10 Min | 1.6 dB Max | |||
30 | 9 dB Min | 1.5 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
20 | 10 dB Min | 1.6 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
30 | 9 dB Min | 1.5 dB Max |
Coupling |
Directivity |
Ins Loss |
Stock |
Checkout |
|
---|---|---|---|---|---|
10 | 12 dB Min | 1.0 dB Max | |||
20 | 12 dB Min | 1.0 dB Max |